Flexible NetFlow Collect Parameters The following table describes the Flexible NetFlow collect parameters. Table 2: Collect Parameters Configuring Flexible NetFlow Flexible NetFlow Collect Parameters Command Purpose match flow cts {source | destination} group-tag Specifies a match to the CTS fields support in FNF record. The following command options are available: • source —Matches to the source of CTS entering the domain. • destination —Matches to the destination of the CTS leaving the domain. Command Purpose collect counter { bytes { layer2 { long } | long } | packets { long } } Collects the counter fields total bytes and total packets.
collect interface {input | output} Collects the fields from the input or output interface. collect timestamp absolute {first | last} Collects the fields for the absolute time the first packet was seen or the absolute time the most recent packet was last seen (in milliseconds). collect transport • packets—packet fields • rcp—RCP fields • tcp—TCP fields Configuring Flexible NetFlow 9