cisco — Configuring a Supplicant Switch with NEAT

Configuring a Supplicant Switch with NEAT Beginning in privileged EXEC mode, follow these steps to configure a switch as a supplicant: Configuring IEEE 802.1x Port-Based Authentication Configuring a Supplicant Switch with NEAT Command or Action Purpose Step 4 interface interface-id Example: Device(config)# interface gigabitethernet 2/0/1 Specifies the port to be configured, and enters interface configuration mode. Step 5 switchport mode access Example: Device(config-if)# switchport mode access Sets the port mode to access. Step 6 authentication port-control auto Example: Device(config-if)# authentication port-control auto Sets the port-authentication mode to auto.

Step 7 dot1x pae authenticator Example: Device(config-if)# dot1x pae authenticator Configures the interface as a port access entity (PAE) authenticator. Step 8 spanning-tree portfast Example: Device(config-if)# spanning-tree portfast trunk Enables Port Fast on an access port connected to a single workstation or server.. Step 9 end Example: Device(config-if)# end Exits interface configuration mode and returns to privileged EXEC mode. Configuring IEEE 802.1x Port-Based Authentication 66