times to calculate the communication path delay. PTP then adjusts current time information network data for the calculated delay, resulting in more accurate time information. This delay measurement principle determines path delay between devices on the network, and the local clocks are adjusted for this delay using a series of messages that are sent between masters and slaves. The one-way delay time is calculated by averaging the path delay of the transmit and receive messages. This calculation assumes a symmetrical communication path; switched networks do not necessarily have symmetrical communication paths, due to the buffering process.
PTP provides a method, using transparent clocks, to measure and account for the delay in a time-interval field in network timing packets, making the switches temporarily transparent to the master and slave nodes on the network. An end-to-end transparent clock forwards all messages on the network the same way that a switch does. Cisco PTP supports multicast PTP messages only. Note The following figure shows a typical 1588 PTP network that includes grandmaster clocks, switches in boundary clock mode, and Intelligent Electronic Device (IEDs) such as a digital relays or protection devices. In this diagram, Master 1 is the grandmaster clock.
If Master 1 becomes unavailable, the boundary clock slaves switch to Master 2 for synchronization. Figure 1: A PTP Network with Switches in Boundary Clock Mode PTP with etherchannel interface and MACsec is supported. Note Configuring Precision Time Protocol (PTP) Message-Based Synchronisation Configuring Precision Time Protocol (PTP) 3