cisco Catalyst 9300 — Synchronizing the Local Clock

2. Port 2 receives and generates timestamp t2 for this message. 3. Port 2 returns and generates timestamp t3 for a Pdelay_Resp message. To minimize errors due to any frequency offset between the two ports, Port 2 returns the Pdelay_Resp message as quickly as possible after the receipt of the Pdelay_Req message. 4. Port 2 returns timestamps t2 and t3 in the Pdelay_Resp and Pdelay_Resp_Follow_Up messages respectively. 5. Port 1 generates timestamp t4 after receiving the Pdelay_Resp message. Port 1 then uses the four timestamps (t1, t2, t3, and t4) to calculate the mean link delay. Figure 3:

Peer-to-Peer Delay Mechanism Synchronizing the Local Clock In an ideal PTP network, the master and slave clock operate at the same frequency. However, drift can occur on the network. Drift is the frequency difference between the master and slave clock. You can compensate for drift by using the timestamp information in the device hardware and follow-up messages (intercepted by the switch) to adjust the frequency of the local clock to match the frequency of the master clock. Configuring Precision Time Protocol (PTP) Synchronizing the Local Clock Configuring Precision Time Protocol (PTP) 7