CW — Nozzle check settings

Chapter3 Handling Nozzle check settings For more details about the nozzle check, see "Auto Nozzle Check System" on page 26 , and for more details about the dot substitution function, see "Complementing Missing Dots due to Clogged Nozzles (Nozzle Verification Technology)" on page 29 . Allows you to change the nozzle check settings. 218 Item Description Nozzle check settings Trigger to Head Maintenance Specify the allowable number of clogged nozzles to be used for the self nozzle check system. Additional auto nozzle check during printing Set whether or not to run the self-nozzle check system during printing.

Nozzle check interval Specify the interval of nozzle check when [Additional auto nozzle check during printing] is set to be performed at the specified interval. Cleaning after self-check Select whether to run an auto cleaning after self-check. Operation when unrecoverable clogged nozzle detected Dot substitution Select whether to enable or disable the Dot substitution function. See "Complementing Missing Dots due to Clogged Nozzles (Nozzle Verification Technology)" on page 29. Operation at unrecoverable clogged nozzle Set the action to be taken when the number of clogged nozzles exceeds the number set at [Trigger to Head Maintenance].