Chapter 3 Commands Mode setting for error & pause signal (output) [Format] ^S(CNA,E,c [Parameter] c [Function] Configure the mode settings for the error & pause signal. If the value of parameter c (mode setting) is 3 or 4, the operation is the same as the service required signal for the external I/F of a Zebra printer. 3 [Initial value] 0 [Examples of command transmissions] Set the error & pause signal to "Normal: High, When an error occurs: Low". The ^JUS command must be used to save the settings to the non-volatile memory in the printer. An example of the command transmission is shown below. It is sent via USB or Ethernet from the computer.
^XA ^S(CNA,E,1 ^JUS ^XZ 31 Description Definition range c = Mode setting D/E/N/0/1/2/3/4 Value for parameter c Description D/0 Turn the error & pause signal (pin 17) OFF (not output). 1 Set the error & pause signal (pin 17) as follows: Normal: High, When an error occurs: Low. E/2 Set the error & pause signal (pin 17) as follows: Normal: Low, When an error occurs: High. 3 Set the error & pause signal (pin 17) as follows: Normal: High, When an error occurs or the printer is paused: Low. N/4 Set the error & pause signal (pin 17) as follows: Normal: Low, When an error occurs or the printer is paused: High.