Chapter3 Handling 2 Make the settings for the barcode type you selected. • Settings for PDF417 ∗ Module Width: Set module width of PDF417. For the recommended value, see "Recommended Module Values (p122)". ∗ Module Height: Specify the ratio of PDF417 module height to the module width. For the recommended value, see "Recommended Module Values (p122)". ∗ Column: Specify the number of columns of PDF417. ∗ Row: Specify the number of rows of PDF417. ∗ Truncation Symbol: Select the check box to create a symbol using data excluding the stop code of PDF417. ∗ Error Correction Level Specify an error correction level for PDF417.
This allows the symbol data to be correctly read even if a portion of the symbol is missing or damaged. The larger the number is, the higher the possibility of data restoration gets. • Settings for MicroPDF417 ∗ Module Width: Set module width of MicroPDF417. For the recommended value, see "Recommended Module Values (p122)". ∗ Module Height: Specify the ratio of MicroPDF417 module height to the module width. For the recommended value, see "Recommended Module Values (p122)". ∗ Column: Specify the number of columns of MicroPDF417. ∗ Row: Specify the number of rows of MicroPDF417. • Settings for QR code ∗ Model: Select a QR code model. ∗ Module: Select a width of a cell (module) of QR code.
For the recommended value, see "Recommended Module Values (p122)" . ∗ Error Correction Level: Specify an error correction level for QR code. This allows the symbol data to be correctly read even if a portion of the symbol is missing or damaged. The possibility of data restoration gets higher in the order of L, M, Q, and H. ∗ Character Mode: Select a mode for data to be converted into a QR code. • Settings for Micro QR code ∗ Version: Specify the version of Micro QR code. ∗ Module: Select a width of a cell (module) of Micro QR code. For the recommended value, see "Recommended Module Values (p122)" . ∗ Error Correction Level: Specify an error correction level for Micro QR code.
This allows the symbol data to be correctly read even if a portion of the symbol is missing or dam- aged. The possibility of data restoration gets higher in the order of L, M. • Settings for MaxiCode ∗ Mode: Select a mode of MaxiCode. • Settings for GS1 DataBar ∗ Module: Set module width of GS1 DataBar. For the recommended value, see "Recommended Module Values (p122)" . ∗ Number of Characters: Specify the max width of GS1 DataBar. Set this if you have selected GS1 DataBar Expanded Stacked. 120