Chapter 3 Creating and Editing Screens 3-180 Revision May, 2010 Property Description of Historical Trend Graph Elements Setting Enable If this option is selected, the following curve options are enabled and can be set. Data No. It is used to set the reading Word data when triggering every time. For example, if the Data Length option in the History Setup dialog box is set to 3words, there are 0 ~ 2 data numbers can be selected in this option. Please note that if the data format is selected as “Floating”, and the Data Length option in the History Setup dialog box is an odd numbers of words, ensure to set the Data No. as an even number. Line Size Used to the display line width.
The range is within 1 ~ 8 and the unit is pixel. Line Color Used to the display line color. Min. Value Max. Value Each display line (curve) can have its min. and max. values. If there are 8 lines in this history data, there will be 8 groups of min. and max. values Grid Line Color Grid Number in Horiz. Please refer to the figure below. The grid color is set to red and the grid number in horizontal direction is set to 3. X Used to set X coordinate Y Used to set Y coordinate Width Used to set the element width Height Used to set the element height