Chapter 3 Creating and Editing Screens Revision May, 2010 3-215 Function Description Cycle Macro Delay Time Sets Macro Cycle Delay time every time this screen is executed. The range of the macro cycle delay time is between 100ms to 5s. Fast Refresh Rate There are three levels of the Fast Refresh Rate and they are High, Medium and Low. The purpose of this function is used to make some elements be displayed immediately when switching screens. Please note that this function is designed to provide fast value refresh speed for the element which performs communication frequently. Therefore, it only allows four elements that can be renewed immediately in each screen.
If the user uses this function on too many elements, it may affect the normal speed of HMI operation. So, we recommend the user not to activate this function if not necessary. Hard Copy Region Setting The user can find this function only in DOP-B series HMI which supports printer function. If the user wants to enable this function, setting the printer in advance is necessary. Please go to Option > Configuration > Printer Setup and select the printer first.
When this function is enabled, if one report list button is created and its assigned output device is a printer, once the user presses the report list button, HMI will refer to the setting in Hard Copy Region option and execute the screen-printing. Top-Left Set the region of HMI printing area (also called Hard Copy Region) and the unit is Pixel. Right-Bottom Need Base Screen Setting Every screen can specify any one of the editing screens as a base screen. When the check box next to Need Base Screen is checked, the base screen will be moved to the back (behind all other elements) as a ground picture.
After compile operation is completed and the screen data is downloaded to HMI, HMI will execute all of the elements on the base screen correctly.