Chapter 3 Creating and Editing Screens 3-244 Revision May, 2010 History Buffer Setup Dialog Box Buffer Properties Export CSV File The column name, i.e. Time, Date, Value 1 ~13 can be user-defined. Please refer to the following figure: Trigger There are two options: Timer and PLC. The sampling action is controlled by the Timer of the HMI or the external controller, i.e. PLC. When PLC option is selected, it indicates that the trigger bit designated by the register for sampling history buffer in the control block control the sampling action. Regarding the settings of the control block, please refer to section 3.4. OK / Cancel Press OK button to save the data and exit.
Press Cancel to exit without saving data. Delete Press Delete button to delete the history data. Modify Press Modify button to modify the history data. History Buffer Setup The calculation method of the size of the history data file is as follows: 1. dat file Each history data will be saved as Hxxxx.dat. xxxx indicates that it is the xxxxth history data. 6Bytes(a)2Bytes(b)N(c) ActualFileSizeMBytes 10241024 a Time and Date Data b History Data Length c Sampling Points a Time and Date Data b History Data Length c Sampling Points