Mitsubishi — 3.14.3.8 Communication

Chapter 3 Creating and Editing Screens  GETCHARS (Get Characters by COM Port) Equation Var1 = GETCHARS (Var2, Var3, Var4) Explanation This command gets characters by COM port. Var1 is the response value after the communication, Var2 is the starting address of transmission data, Var3 is the data length, and Var4 is the allowance communication time (unit is ms). The result will be stored in Var1. Remark  Var1: Response value after communication 1: Completed normally 0: Failed  Var1 and Var2 can be internal memory only. Var3 and Var4 can be internal memory or constant. Example Get three consecutive WORD data starting from $1 and store the result in $0.

 SELECTCOM (Select COM Port) Equation SELECTCOM (Var1) Explanation This command is used to select COM port. When not connecting to the external controller (set PLC to NULL) in Options > Configuration in Screen Editor software program, the user can use two COM ports (0:COM1, 1:COM2, 3:COM3 (for some models only)) at the same time. Revision May, 2010 3-359