Mitsubishi — B.1 Upload and Download DVP Series PLC Programs

Appendix B New Upload/Download Function Notes: 1. The file name of PLC programs should be DVP-xxx.dvp (xxx must be a number between 000 to 999). 2. If the PLC program is a new file, select New.. and then touch Upload icon on the screen to add it into the file directory. 3. The supporting version and series of DVP series PLCs are listed in the table below: 4. HMI Transfer Mode is available for uploading and downloading DVP series PLC programs (*.dvp) only. It is not provided for the upload and download of the subroutine, ladder diagram, SFC chart, note of device name and row, non-volatile data, label structure, symbol structure, etc. data.

Revision May, 2010 B-3 DVP Series Support Password Examination Support Verification Code Limit PLC Limit Function Function ES X X ES2 V1.0 and later version V1.0 and later version EX X X EC X X SS X X SA V 1.7 and later version V 1.7 and later version SX V 1.7 and later version V 1.7 and later version SC V 1.5 and later version V 1.5 and later version SV V 1.2 and later version V1.3 and later version EH X X EH2 V 1.1 and later version V1.3 and later version EH2-L V1.0 and later version V1.0 and later version