Appendix C Multi-Link Connection This chapter describes the connecting methods used to connect multiple HMIs to one or mor external controllers, i.e. PLCs. The connecting method for multi-link connection is shown as the figure below. The Ethernet and COM2 serial port of HMIs are used. HMI 2 172.16.190.2 Ethernet HMI 2 reads the data of HMI 3 reads the data of PLC 1 via Ethernet PLC 1 via Ethernet COM2 / RS-485 PLC 1 In the figure above, three HMIs, HMI 1, HMI 2 and HMI 3 are connected via Ethernet. Only HMI 1is connected to PLC 1 by using COM2 serial port through RS-485 communication. HMI 2 and HMI 3 are not connected to any external controller.
However, through 1:N connection, HMI 2 and HMI 3 are able to access the registers of PLC 1 via Etherent. Revision May, 2010 C-1 HMI 1 172.16.190.1 Ethernet HMI 3 172.16.190.3