U.S. Army ADS-79D-HDBK — ADS-79D-HDBK.pdf

Downloaded from https://www.everyspec.com ADS-79D-HDBK 47 TABLE B-II.

Data streams used in regime recognition processes with Individual component fatigue damage assessment Number Type of Data Purpose Category 1 Bus Data Stored by DSC to Enable Regime Recognition Inherent 2 Raw Parametric Data Stored at Local Unit (by BAMO, LAR, LE, etc.) for Unit Purposes Unit Discretion 3 Raw Parametric Data Processed by Regime Recognition Algorithm Inherent 4 Raw Parametric Data Troubleshooting Regime Recognition Algorithm for Unidentified Intervals On Condition Auditing Regime Recognition Algorithms Statistical Sampling 5 Regime Data Stored at Local Unit (by BAMO, LAR, LE, etc.) for Unit Purposes Unit Discretion 6 Regime Data Processed by Component Life Expenditure Calculator Inherent 7 Regime Data Usage Monitoring and Storage for Potential Usage Spectrum Updates Required 8 Damage Fraction/Life Data Stored at Local Unit (by BAMO, LAR, LE, etc.) for Unit Purposes Unit Discretion 9 Damage Fraction/Life Data Auditing Component Life Expenditure Calculator Statistical Sampling 10 Substantiating Data Maintenance Engineering Call (MEC) Substantiation Unit Discretion 11 Substantiating Data Usage Spectrum Monitoring Periodic Usage Spectrum Updates On Condition 12 Damage Fraction/Life Data Tracked in Logbook Inherent