U.S. Army ADS-79D-HDBK — ADS-79D-HDBK.pdf

Downloaded from https://www.everyspec.com ADS-79D-HDBK 49 TABLE B-III.

Data streams used in load monitoring and estimation processes Number Type of Data Purpose Category 1 Aircraft Source Data Stored by DSC to Enable Loads Monitoring and Estimation Inherent 2 Raw Bus and Loads Data Stored at Local Unit (by BAMO, LAR, LE, etc.) for Unit Purposes Unit Discretion 3 Raw Bus and Loads Data Processed by Measured Load Post- processor and Load Estimation Model Inherent 4 Raw Bus and Loads Data Troubleshooting Load Monitoring and Estimation On Condition Auditing Load Monitoring Post- processor and Load Estimation Model Statistical Sampling 5 Processed Loads Data Stored at Local Unit (by BAMO, LAR, LE, etc.) for Unit Purposes Unit Discretion 6 Processed Loads Data Processed by Component Life Expenditure Calculator Inherent 7 Processed Loads Data Usage/Loads Monitoring and Storage for Potential Usage/Loads Spectrum Updates Required 8 Damage Fraction/Life Data Stored at Local Unit (by BAMO, LAR, LE, etc.) for Unit Purposes Unit Discretion 9 Damage Fraction/Life Data Auditing Component Life Expenditure Calculator Statistical Sampling 10 Substantiating Data Maintenance Engineering Call (MEC) Substantiation Unit Discretion 11 Substantiating Data Usage/Loads Spectrum Monitoring Periodic Usage/Loads Spectrum Updates On Condition 12 Damage Fraction/Life Data Tracked in Logbook Inherent