US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors

Downloaded from https://www.everyspec.com At"P 706-117 TABLE 4-6. VIBRATION INDUCED DAMAGE TO ELECTRICAL AND ELECTRONIC EOUIPMENT Metf 37) Compoent category Canage Observations Cabinet anid frame Among some 2o0 equiament cabinet and fraP. structures subjected structures to shock and vibration, damage fiCluded 30 permanent deforms- tloan, 17 fractures In arets% of iutr~ss concentration. two fractures at no apparent stress concentrations. 23 fractures In or near welds. and 26 miscellaneous undefined failures. Chassis Nearly 300 chassis subjected to shock and vibration experienced 18 permanent doforeacions, eight frataueas in or near welds, nine fractures at no apparent stress concentrations.

46 fractures at points of stress concentration, and 12 .4iscellana- ous failures. Cathode-ray tubes Cathode-ray (CR) tubes are susceptible to vibration aaei they are improperly moun ted and supported. CR tbs ?'th SCreana2 larger than 6 In. 4r# Particularly Susceptible. Of 31 Cathode-ray tubes subjected to shock sand vibration, the a deflection plates, of one tube became deformed, another had a filament failure. fiee suffemil envelope fractures, and one had a glaue-~ocket seal break. IN.ters and indicators Although the moving call type Of Meter Wormane the majority of units in this catenory, other Indicators such as Bourdon tubes and drive-type synchros were also tested.

Of the latter group, moat of the failures were either erratic performance or zero shift difficulties. Nearly 200 units were subjected to shock and vibration, Two suffered permanent defonriatinn If the case. one had elonments Inralened. 19 1%ve frr~tlr ',4' .io. hod the glass face fractutad. cwo oov.'ioaJ internal opt circuits, two had loose or Jrjeiwv .. j-? 5 th .4a had deformed pointers, and 10 others failed from miscellaneous causes. Relays Relays present a particularly difficult problem for d na1mic conditions because of the difficulty In balancing al I o the mechanical moments, Shock generally causes failure In the form Of the armature failing to hold during the shock.

A total of 300 relays wore subjected to shock and vibration. Atrneturt difficulties accounted for 29 defect%, four relays had contacts fuse or barn tecause of arcing, nsa had the Coil loosened on the pivots, two had the springs disengaged from the armature. and four sustained miscellaneous defacts. Wiring Wiring failure from shock end vibration Is a serious problem. A defect not only results in malfunctioning of the equipment but grotenats a difficult troubleshooting job In locating the wire reat,.In a number of equipments subjected to shock and vibra- tion, the failures were as follows: 10 cold solder joints "*oend, 14 lead-supported component-, had the leads fail.

insufficient clearance caused three Cases of arcing, and Insufficient slack caussed nine lead failurns. In addition. three plastic cable clamps fractured. 14 solder jo Ints or connections failled, 16 solid coaductor wires broke, and 92 sustained miscellaneous failures. Transformers In electronic equipments transformers are probably the heaviest and densest components found on an electronic chassis. Because of the weiht and size of transformaers, shock and vibration aer more likely, to p roduce menchanical rather than electrical failures.

While not all mechanical failures Immnediately prevent the transforrer from functioning properly, they even- tually result in destructiono of the transformer and damage to surrounding componenats. Of 80 transformers subjected to shock and vibratio, 11 had the mounting stubs bakat the weld, four had the bottom frame fall, and twosffered brote internal leads due to motion of the coil in the case 4-46