US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors

Downloaded from https://www.everyspec.com AMCP 70-.117 from Federal Test Method, Standard 1011, are summa- in MIL-STD-810 (Ref, 51) and in USATECOM MTP rized, in Table 4-13. 4-2-804 (Ref. 82). These specificatic•s were developed MIL-STD-33 i, Test 104.1, is a vibration test com- through extensive road testing and reduction of data at monly used for the transport of explosive materials. It Aberdeen Proving• Ground. Tests were conducted on includes two procedures, which are described in Table three types of military vehicles: tractor-trailers, tracked 4-14. Procedure I includes a cycling test and a resonance vehicles, and two-wheeled trailers.

In addition, both test, and Procedure 2 includes only a cycling test over specifications relate Ahe •:.at duration to the actual dis- a restricted frequency range. tance and/or td':, v f transport. The vibration environ- Most bounce tests are performed c.n special testing mert is simulsted to a much 1,swer degree in the reso- machines having a I in. peak-to-peak displacement. nance test, which should be viewed as a damage Other paiameters to be specified during bounce tests simulation test. In this test it is assumed that vibra- are the frequency (or peak vibrational acceleration) and tional damage results almost entirely from vibrational test duration.

A summary of a number of the major inputs at those frequencies for which the package ex- bounce test specifications is given in Table 4-15. hibits resonance. Another explicit ,ssumption in the Cycling tests require specification of the amplitude resonance test is that damage incurred by simultaneous versus frequency schedules, the test duration, and the excitation at a number of frequencies is equivalent to details of the sweep; i.e., type of sweep and sweep rate. the cumulative damage resulting from separate excita- The amplitude versus frequency schedules are given in tion at each of those frequencies as experienced in the the pertinent specifications. Table 4-16 is a summary of test.

Emphasis in the major test specifications is much the specified test durations per axis for the major heavier on the resonance test than on the cycling test; specifications, and Table 4-17 is a summary of the speci- for example, MIL-STD-810 (Method 514.1) requires fied sweeps. two-thirds of the testing time for tied-down packages to The resonance test consists of a resonance search be devoted to the resonant dwells. followed by dwells at the resonant frequency discov- The bounce test provides the least degree of environ- ered. Specifications do not vary greatly from one to the mental simulation.

Even so, it hus received very wide other on the resonant search, which is conducted as a acceptance, partly because it is useful in estimating the sweep at levels somewhat lower than used in the cycling endurance of a package subject to transport vibrations. tests. The specifications do not specify the positions of Good correlation between results in bounce and per- the accelerometers or the number of accelerometers to formance in vehicular tests has been demonstrated. A be emp'oyed.

As a result, accelerometer locations must package that is tested by the bounce test is, in effect, be chosen appropriate to the package being tested, it subjected to a great many low velocity impacts with the being presumed that the accelerometer should be wooden testing platform. The shocks resulting from located in positions appropriate to detect any reso- these impacts generate very broad spectrum vibrations nances that may occur during the search.

When a speci- in the package, so that it might be supposed that all fication requires a cycling test in addition to resonance package resonances should receive some excitation tests, the dwell levels at the resonant test are usually from these recurring impacts. Whatever the vibration taken the same as in the arnplitude-frequency scheaule of the cycling test. If the resonance search fails to reveal test employed, for those packages constructed from any resonances, then the resonant dwells are often re- humidity-degradable materials, it is recommended that placed by additional cycling time.

Table 4-18 is a sum- a preconditioning exposure to a high humidity atmos- mary of several resonance test specifications. The fre. phere be given prior to testing. Such preconditioning is quency ranges to be employed in the resonant sear.-h, generaily required for all types of loading tests. the dwell time to be us'ed at each resonant frequency, In order to demonstrate the quantity of military 3nd an indication of the dwell level are given, specifications pertinent to vibration testing and to None of these vibration tests duplicate or presume to make some additional comparisons among these duplicate actual transport vibrational environments.

It specifications, the results of a recently conducted sur- is recognized that duplication of the actual environ- vey of vibration test procedures in use by the Air Force nwnt would be too costly and time-consuming. Ran- is reviewed (Ref. 83). In this survey, specifications and dom vibration testing at accelerated levels also has not standards containing vibration test procedures in use been employed for pa,.kage testing due to the higher by the Air Force are compiled. A representative sample cost.

The most serious approaches toward environmen- of hardware specifications was examined to establish tal simulation have been taken in the area of the cycling the direction and extent of use of vibration tests offered tests, particularly those of the land transport schedules in the various test specifications and standards. A total 4-72