Downloaded from https://www.everyspec.com AMCP 706.117 TABLE 4.14. VIBRATION TEST FROM MIL4TD-331 (Ref. 68) PROCEDURE I 1. Cycling test is divided into two ranges, 10-60 Hz and 60-500 Hz. Ten sweeps per axis (10-60-10 Hz) are taken over the lower range and 14 sweeps per axis over the high range (60-500-60). A logarithmic sweep is specified such that each sweep requires 20 min. The amplitude schedules are given in the specification. 2. Resonance test consists of a 20-mmn dwell at each resonant frequency, the amplitude taken as In the cycling test. If no resonances are found, two extra 15-mmn sweeps are required in each of the cycling ranges. 3. A discrete frequency alternate is allowed.
For the cycling test, this alternate requires 60-mmn dwells at each of the following frequencies: a. Lonqitudinal axis: 10, 17, 28, 46, 76, 128, 212, 350 Hz b. Transverse axis 1: 12, 20, 33, 54, 91, 152, 250, 417 Hz c. Transverse axis 1I: 14, 24, 38, 65, 107, 178, 297, 500 Hz If no resonances are detected, the resonant dwells are replaced by 15-mmn dwells (each axis) at 10, 46, 152, and 500 Hz. PROCEDURE I I 1. Cycling test over range 10-60 Hz requires 16 logarithmic sweeps (10-60-10 Hz) of 15-mmn duration, following the schedule given in the specification. 2. The discrete frequency alternate requires 10 min each at the following frequencies: 10, 11, 12, 14, 15.
16, 17, lb, 20, 22, 24, 26, 28, 30, 32, 35, 38, 41, 44, 47, 51, 55, 60 Hz. METHOD 5019 1. Bounce test is taken at 1-In. double amplitude at a frequency such that a 1/16-in. feeler may be slid freely between speci- men and platforMor, alternatively at a 1-G peak acceleration. Test time is 2 hir if testting In only one position or 3 hr if testad in more than one position. 4-74