US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors

Downloaded from https://www.everyspec.com AMCP 706-117 TABLE 4.21. CYCLING TEST PARAMETERS (Ref. 83) Double Total For equipment ampl., Accel., Freq., vib. mounted on in. 9 Hz time, hr Recip. and gas turb. eng. 0.036-0.10 1-20 5-500 9 Turbojet engine 0.036-0.10 1-20 5-2,000 9 Aircraft structure on mounts 0.010 2 5-500 9 Helicop. structure on mounts 0.036-0.10 2-5 5-500 9 Helicop. structure, no mounts 0.10 2 5-500 9 Air-launched mi ssi les, captive phase 0.036-0.10 1-10 5-500 6 Air-launched missiles 0.036-0.10 1-10 5-2,000 1.5 Grnd-launched missiles 0.06-0.20 1-50 5-2,000 1.5 Grnd. supt.

vehicles 0.06-0.10 1-50 5-2,000 9 Double IFrequency Equipment amplitude, Acceleration, range, Total test type in. g Hz time, hr TABLE 4-22. ENDURANCE TEST PARAMETERS (Ref. 83) Microelectronic 0.06 20 20-60 96 Suspended store 0.03 10 50 300 En~ ne mounted 0.01-0.05 20 15-250 36 (on turbojet or turbofan) 4-79