US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors

Downloaded from https://www.everyspec.com AMCP 706.117 track and rocket sled. Because it is not possible, in all DIRECTION cases, to reproduce the exact natural environment with OF either a rocket sled or centrifuge alone, it may be neces- FLIGHT sary to employ a combination of tests for a full investi- gation of the physical processes leading to the degrada- I tion or failure of the equipment being tested. The test parameters that may affect the type and degree of fail- ure are (I) acceleration level, (2) time duration of the test, (3) jerk, i.e., rate of change of acceleration, and (4) direction of acceleration. Perhaps t0 .

simplest means of simulating a zero-G environment is by placing the specimen in free fall (Ref. 17). However, simply dropping the specimen through the atmosphere is inadequate since the buildup of air drag rapidly results in the disappearance of the force. To surmount this problem, the specimen container is placed in a second container or blast shield. Most such facilities are limited to approximaate~y 10 s, which re- COMP"OENT "111 stricts the specimen volume to a few cubic centimeters. To increase the duration of the zero-G periods, air- craft flying a parabolic flight path have been utilized.

The aircraft goes into a shallow dive to build up air- speed, then makes a 2.5.0 pullup to start the zero-G portion of the flight which continues over the top of the FIGURE 6-12. Component Mounted on a Vehicle parabola and downward until the airspeed builds up to In Motion (Ref. 20). certain limits at which time a 2.5-0 pullout is executed and the aircraft resumes normal flight. Periods of weightlessness in excess of 40 s have beer achieved in this manner (Ref. 18). For packaged equipment, insofar as the package ex- TEST SPECIMEN terior is c6ncerned, acceleration loads could be repre--'-Q COMPONENT sented by static loading.

However, for complex pack- ages and containers and for packages with isolation systems, a static load test cannot simulate the relation- ship between package and contents (Ref: 19). If this relationship is believed to be critical to the performance of the package, an acceleration test must be performed R to evaluate the transportability of the package. Of course, the test must be conducted on the complete package (i.e., with the actual or simulated conterats in place) to achieve valid results. In simulating a linear acceleration by means uf a rotary accelerator or centrifuge, the test item must be mounted so that the resulting force will be in the proper direction.

A component, package, or system mounted or stored in a vehicle whose direction of motion is as shown in Fig. 6.12, must be mounted on the centrifuge as shown in Fig. 6-13 in order to achieve a valid test (Ref. 20). Two disadvantages hinder the simulation of a linear azceleration with a centrifuge. One is that any devia- FIGURE 6-13. Proper Mounting of Teat Specnern tion in angular velocity results in a tangential accelera- on Contrilfup (Componenrt I A" In fig 6-12) 'on, which in effect changes the magnitude and direc- (Ref. 20). 6.13