US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors

Downloaded from https://www.everyspec.com AMCP 706-117 TABLE 7-1. TERMS AND UNITS USED IN ACOUSTICS Physical Psychological Term Unit Term Unit Frequency Hertz (Hz) Pitch Mel Amplitude Decibel (dB) te 20 UN m"2 Loudness Phon Newtons/meter2 (N m2 ) Sone Dynes/centimeter 2 (dyn cm 2 ) Microbar (.bar) Pounds/inch 2 (psi) Duration Seconds; minutes Duration Seconds; minutes In Enrlish units (4) Frequency. The unit of frequency is hertz (Hz); i.e., cycles per second, Nominally, the h'iman range of C = 49. 03V'R, ft see'* (7-3) aurally detectable sounds is 20 to 20,000 Hz. Pressure oscillations at frequencies above this range are called ultrasonic waves or ultrasound.

These frequencies can- not be heard by man, but at high SPL they produce R = temperature in degrees Rankine some biological effects and are discussed in a later para- (459.7 plus the temperature in graph. The effects of infrasonic frequencies ( 20Hz) degrees Fahrenheit). At 70F Pre also covered briefly. The terms "supersonic" and the speed of sound at sea level "subsonic", which are related to the speed of sound, is about 1,12b fts- t 1. should not be confused with those terms when used to describe frequency range. (3) Wawlength.

The wavelength h of a sound is tl d i n distance the wave travels during one period or cycle, It When describing sound, measuring only the overall is related to the speed of sound and to frequency by the SPL is not sufficient. The sound must also be analyzed equation to determine how the sound energy is distributed over the frequency range.

A sound is usually analyzed by passing it through a constant-percentage bandwidth filter, such as an octave-hand analyzer, in which each x a C/f (7-4) pasaband has upper and lower limiting frequencies hav- ing a ratio of 2:1, An octave-band analysis is usu-Lly sufficient to determine the effect of steady'state noise upon human beings and the sutrounding community. A 1/3-octave (or narrower) analysis is required when where localizing the component in a system that is the major C = speed of sound, m s' or ft 9-1 contributor to a noise problem, or if the noise contains f - frequency, Hz a pronounced narrow-band frequency component.

For example, during one period a I00-Hz wave would The "preferred" series of octave bands for acoustical move 3.44 m or 11.3 ft at 70"F (21. 1C). From Eq. 7-4, measurements is identified as multiples and submulti- as frequency increasm, wavelength becomes shorter. ples of 1,000 Hz, which describe the center frequency 7-2