US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors

Downloaded from https://www.everyspec.com AMCP 706-117 TABLE 84. MAXIMUM PERMITTED EXPOSURE TO LASER ENERGY (Ref. 34) Permitted energy Condition Type of Time or pulse density falling pulse duration on retina I. Single pulse 0.001 to I us 0.001J cm"2 2. Single or 1 to 1,000 us 0.01 J cm"2 train of pulses 3. Pulses or 0.1 s 0.1 J cm" 2 train of pulses 4. Continuous-wave laser power incident upon the retina shall not exceed that value which makes ab - 1.0; where a - power at the retina W cm" 2 and b a greatest dimension of the image on the retina, mm. 5. Any part of body except eye: total incident laser energy during any 1-j period shall not exceed 0.1 J cm-.

Acceptable alternatives to the above conditions: Condition 1. Where the eye cannot resolve the image, the nergy density at the pupll of the eye must not exceed 0.02 erg cm indoors or 0.2 erg cm- in bright sunlight out-of-doors. Where the eye can resolve the image from a diffuse reflector, viewing is permissible if the energy density aj the diffuse reflector does not exceed 0.03 J cm-z indoors or 0.3 J cm- in bright sunlight out-of-doors. These levels must be reduced threefold if optical glint occurs. Condition 2. Same as alternatives to Condition 1, except permissible energy den- sity is increased by a factor of 10. Condition 3.

A continuous-wave laser of power output less than 50 pW may be viewed under any conditions. 8-32