US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors

Downloaded from https://www.everyspec.com AMP n6S11t7 iug include absorption or emission of energy in the be determined reacts with a color-tormlng reagent.. The electromagnetic spec~trum, light scattering, reflectance, reultant color Is proportional to the pollutant concen- and ionization. Sonme of the most recently developed tration and sampling time. instruments use a chemiluminescent detection method. Colorimetric analyzers are available for the continu- This involves the measurement of light energy released ous measurement of sulfuar dioxide, nitrogen dioxide, when the pollutant gas reacts with certain other Soo and oxidants. The colorimetric principle is the refer- or reagents.

ence method for measuring sulfur dioxide and nitrogen Table 2-15 (Ref. 31) lists the different measuring dioxide (see par. 2-6.3, "Reference Methods"). methds lon wit thir ppliatins.Tabl 2.6 (ef. Fig. 2-20 is a flow diagram of a typical colorimetric 32)sumariesthesamlig tchnqus ad caIfie type monitor. This is a dual-flow colorimeter in which 32)n smaccrdinges thei usemplingtatechniusanizd , or~i the absorbance of the unreacted reagent is measured athem acrigt hi sssatic, mechnizeso and used as the zero reference for the sample (reacted) solution.

As shown in the diagram, the light source is split with equally intense beams passing through the 246.1 MEASUREMENT PRINCIPLESa reference cell and the sample cell where in both cases the transmitted light is detected by photocells. The The measuring principles that have round significant difference in intensity of the transmitted beams is a application in air pollution monitors are briefly dis- function of the pollutant concentration and the length cussed: of the light path through the solution. The actual flow (1) Colortmetry.

Colasimetry involves the absorption of the air sample through the monitor starts with the of visible or near ultraviolet energy by colored corn- atmospheric sample passing through the rotameter into pounds. In oolorimetric Instrument~s, sample air Is drawn the scrubber or absorber. Here, the pollutant reacts through an aqueous solution in which the pollutant to with the reagent. From the scrubber the air sample is discharged to the atmosphere and the reacted reagent S. General referonces for this paragraph are Rota. S1 and passes into the sample cell where the absorbance or the 88. solution is measured.

SAMPLE VALVEVACUUM SCRUBBERJ ROTA METER LIGHT 0 LENS LIQUID REAGENT FI R i CHTO P MP LRESER VOIRl SAMPL _: = rEFPOT PHOTO CELL KA L CELL jLIHCEL PM LIQUIDDETECTION CIRCUI7T RECORDER FIGURE 2-20. Schematlc Diagewn of a Typical Co/ar/merkc Mon itor