Downloaded from https://www.everyspec.com AMCP 70-117 METERNG -CAPILLARY эIJUID PUMP I "COLUMN] VACUUM VALVE II/PM A IR SODA- I LIME t0 TUBE AIR RELIEF AIR FLOW LUIVALVE REG. VALVE LIQUID CHECK CELL II -METER OVERFLOW FILLER I CONSTANT )*STOPCOCK C HEAD TUBE -CONDENSATE L/CONDUCTANC I SUPPLY L __ , RI BOTTLE DRAI DRAIN CUP FIGURE 2.22. Sdmhtr c Di.gram of a Typkcal Sulfur Dioxide Conductivity Monitor phototube or photomultiplier tube and associated elec. measuring nitrogen oxides. Fig. 2-25 is a schematic tronics. A schematic diagram of a typical flame pho- diagram of a chemiluminescent nitric oxide analyzer. tometric sulfur monitor is given in Fig. 2-23.
In this instrument the phototube is used to detect the (5) Flame ionizatian When hydrocarbons are tight emitted from the chemiluminescent gas phase burned in a hydrogen flame, a flow of ions is produced reaction of nitric oxide and ozone according to the which can be measured electrically. The number of ions following reaction produced by a hydrocarbon molecule is proportional to the nmomber of carbon atoms in the molecule. There- NO + 0 3 NO-N + 90 " NO 2 + 03 + h&' fore, this technique is not specific for particular hydro- (2-18) carbon. The energy from a hydrogen flame is not suffi- cient to ionize most other gases. Fig.
2-24 is a schematic where NO; indicates an excited state of nitrogen diox- diagram ofa typical flame ionization monitor. A more ide that emits a photon (1,) and becomes stable nitro- detailed discussion of this method is given in par. 2-6.3 gen dioxide as indicated. as the reference method for measuring hydrocarbons. (7) Irfrared obxorptiom Certain pollutant mole- energy are produced by certain chemical reactions. tion spectrum that the absorption of infrared energy Such reactions are being used to measure ozone and can be used as a measure of the concentration of a (6) Chemiluminence. Small quantities of light cules have a sufficiently characteristic infrared abanrp- nitric oxide.
When the pollutant of interest reacts with pollutant. Carbon monoxide is uniquely suited to this certain other gpase or reagents, the quantity of light technique of detection since its absorption characteris- released is proportional to the pollutant concentration, tics and typical con"n:rations make possible direct This technique is usually highly specific for a given sampling. Nondispersive infrared spectrometry is the pollutant. It has been designated as the reference reference method for measuring carbon monoxide and method for measuring photochemical oxidants (ozone) is discussed in more detail in par. 2-6.3.
and is proving to be, perhaps, the best method for (8) Suspended particulate& Suspended particulates 240