US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors

Downloaded from https://www.everyspec.com AMCP 706-117 AMBIENT AIR SAMPLE INLET TOGGLE VALVE NOLI[NOtOD /VALVE - MICRON FILTER : AUXILIARY NEEDLE VALVE €ORS rlTK'MICRoNONII/ •FILTER SOZI T ORl'rfI[UT"• CAS FITRSNCORIFICE so1,11 OIFC COARS FILTER 3-WAY SOLENOID LOW PRESSURE COARSE FILTER HTUB REGULATOR LWPESR EUAO GAIS VACUUM GAGE REACT*011*. L COOLED HCUSII.3 l i !,OY GAS j ~ ~CUUM -OPTICAL OE SPL WINDlOW VACUIUM fiNE ,.. _. - PuMP MEASURING _-.RECO•.ER OJ?P'ut PROGRAMMER ELECTRONICS ,,--,.,TER. FIGURE 2-25. Schematic Diagram of a Chemiluminesen!

Nitric Oxide Analyzer can be measured in a variety of ways, The selection of provides maximum quality control in the collection of a particular technioue should be determined by the reliable data (Ref. 31). environmental conditions under which the measure- Most prei, it-day monitoring instruments are sub. ments are to be made and the objectives of the measur- ject to drift arik variation in internal parameters; there- Ing program, fore, they do not maintain accurate calibration ovcr Perhaps the most reliable method, and the only one to long periods of time. It is necessary to check and stand- be discussed here, for determining the mass concen- ardize operating parameters on a periodic basis.

These tratlon of iuspended partIcilate matter Is filtration. The are predetermined by the manufacturer and usually are measurement of suspended particulate matter by lli. listed in the operator's manual. tratlon Is accomplished using a high-volume sampler. To calibrate an instrument, the method used must Alo, for sampling periods less than 24 hr, a tape sampler deliver a known pollutant quantity to the system. The can be used. Both systems are described In par. 2-6.3.

Equipment and techniques for measuring particle instrument must be calibrated in the monitoring nmode number and size distributions of pariculate pollutante and should sample the calibrating gas at identical set- are discussed in detail by Giever (Ref. 34). tings and flow rates at which the instrument will oper- ate in the field. The calibration involves measuring and 2-6.2 CALIBRATION TECHNIQUES adjusting all instrument parameters or subsystems that have a direct bearing on measurement.

Typically this The validity of the data derived from air monitoring includes flow rates, base line, lag and response time, instrumentation is dependent upon the type and extent and system response to an input of known standard of the quality control procedures employed. The first pollutant concentrations over the entire operating and perhaps most critical element of data quality con- range. Since input levels are varied and instrument trol is instrument calibration. Calibration determines parameters are adjusted during this process, it is re- the relationship between the observed and true values ferred to as dynamic or multipoint calibration. A cali- of the variable being measured.

Instrument calibration bration check, by which a known amount of pollutant 2.41