US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors

Downloaded from https://www.everyspec.com AMCP 706.117 (4) Sampling Technique sumptions allowed the following constraints to be used (a) Location of sampler in the derivation: 2 Height above terrain equal to or less than 0.75 pm in diam,.ter. I Distance from dust source (1) Fifty percent of the number of particles are 3 Location with respect to wind direction (2) Ninety percent of the number of particles are (b) Sampling time equal to or less than 2,5 jkm in diameter. (c) Sampler characteristics, (3) Ninety percent of the weight of the sample is composed of particles greater than 3 j.m in diameter.

This equation may only be valid for a sample meeting 3-2.1 CONCENTRATION the three constraintr; the accuracy of the conversion 3-2.1.1 Method of Expression decreases as the sample deviates from those values (Ref. 4), In general, the assumptions are not fulfilled Concentration is one of the most important parame- and this conversion is difficult to make. ters used in describing a sand and dust environment. Quantitative expressions of concentration are useless, 3.2.1.2 Typical Atmospheric however, unless the conditions under which the meas- Concentrations urements were made are described adequately and the The concentration of sand and dust in the atmos- range of particle sizes is specified.

Concentration values phere varies widely with geographic location, climatic for a given test are highly sensitive to such variables as conditions, and the degree of activity. In metropolitan the dust producer, climatology, the terrain, and the and industrial areas, industrial activity may be the ma. sampling technique. jor source of atmospheric dust. Pauly (Ref. 6) reported Concentration can be expressed as number of partilese concentration ranges, as given in Table 3-1, of atmos- per unit volume of air or as the weight of particles per pheric dust measured at various points within regions unit volume. Both expressions are used in the literature, having a temperate climate.

Although these data may However, weight per unit volume Is the most common not be quantit~tive, they show that atmospheric dust is term in test specifications. Optical measuring Instru- always present in varying amounts throughout the ments are used occasionally and give concentration In country. In general, this variation is more related to air particles per unit volume. Weight-per-unit-volume data pollution than to natural sand and dust. are usually given in grams per cubic meter in countries using the cgs system and in grams per cubic foot in the 3-2.1.3 Concentration vs Altitude in United States and Great Britain (g ft"3 X35,3 = g m' 3 ).

Dustatorms To convert particles per unit volume to weight !er unit volume, or vice versa, one has to know something Typical concentration values are presented in Table about the particle size distribution, particle shape, and 3-2 from measurements made at various altitudes by average density of the sample. The information can be gained from (I) a size analysis, (2) visual or microscopic inspection, and (3) chemical and mineralogical analy- TABLE 3.1. DUST CONCENTRATIONS IN sis. One such conversion for air-floated dirt in Arizona VARIOUS REGIONS was reported by Engelhardt and Knebel (Ref. 4): C,, = 3.894 x 10' C~, g ftt (3-1) Average dust Region concentration, Pg ft" 3 where C.

= concentration, g ft-3 C,, = concentration, million particles ft" Rural and suburban 1.3 to 3.2 In deriving the equation, it was assumed that the parti- Metropol I tan 3.2 to 13.0 cle distribution followed certain conditions and that particles were similar in size to those found in previous Industrial 13.0 to 48.5 measurements of air-floated dirt in Arizona. These as- 3-2