everyspec.com n/a — MIL-HDBK-502: Department of Defense Acquisition Logistics Handbook PDF Download

Downloaded from https://www.everyspec.com MIL-HDBK-502: A MIL-HDBK-502: A CQUISITION CQUISITION L OGISTICS OGISTICS MAINTENANCE PLANNING SUMMARY SECTION I: GENERAL Inspection/fault location to be accomplished by organizational maintenance, with follow-on inspection/fault location and replacement of door-screen and engine assemblies performed by intermediate support as well as the replacement of compressor and repair of all assemblies except the wire harness, which requires the attention of depot maintenance. SECTION II:

MAINTENANCE ACTIONS ITEM NAME ACTION ESTIMATED TIME MAINT LEVEL engine overhaul 4 hours DEPOT pistons remove&relace 1.13 hours INTERMED plugs remove&replace .75 hours INTERMED radio fault locate .25 hours ORG Figure 7-2. Sample Maintenance Planning Summary Engineering and logistics functional elements must coordinate and interface to maximize the usage of the data developed by each program element. Effective coordination can eliminate costly duplications of effort. The precursor to maintenance planning information is RAM data.

The following excerpt from DoD 5000.2-R, paragraph 4.3.6, reveals this link, “ Reliability requirements shall address both mission reliability and logistic reliability. Maintainability requirements shall address servicing, preventive, and corrective maintenance.” A maintenance planning summary may include supporting information from the RAM community that justifies the need for each maintenance action (e.g., failure modes, etc.). Other reliability and maintainability data that could also be incorporated includes, but is not limited to:

task frequency, failure rate of an item or mean time between failure, mean time to repair an item, mean time between maintenance actions, mean time between removals, and operational availability (A o ). 7.3.3 Repair Analysis Purpose and Content These reports summarize the conclusions and recommendations of the repair level analysis. The government may verify the conclusions and recommendations by using contractor’s inputs to perform an in-house 7-8