mean-well DRS - 240 / 480 Series — Mean Well DRS 240/480 Series Power Supply User Manual PDF

5 MFR_ID_B6B11( - 0x0083 is the last 6 codes of the manufacturer s' MFR_ID_B0B5( - 0x0080 is the first 6 codes of the manufacturer s' EX: manufacturer s name is MEANWELL→MFR ID_B0B5 is ; ' _ MEANWE Byte 5 0x45 Byte 5 0x20 MFR_MODEL_B6B11 (0x0089 is the last 6 codes of the Byte 3 Byte 4 Byte 5 0x52 0x2D 0x34 0x38 Byte 9 Byte 10 Byte 11 0x34 0x20 0x20 MFR_MODEL_B0B5 (0x0086 is the first 6 codes of the EX: Model name is DRS-480-24→MFRMODEL_B0B5 is ; DRS-48 Bit 7 HI_TEMP: High ambient temperature protection Byte 4 0x57 Byte 4 0x20 Reserved: Currently not in use, retain (default is 0) Note:

Unsupported settings displays with 0 1=Abnormal ambient temperature Byte 3 0x4E Byte 3 0x20 MFR_MODEL_B0B5 MFR_ID_B6B11 manufacturer ' manufacturer s model name (ASCII) ' 26 MFR_MODEL_B6B11 is 0-24 Byte 0 Byte 1 Byte 2 Byte 7 MFR_ID_B6B11 is LL Byte 1 0x45 Byte 1 0x4C High byte: Bit 0:7 0x2D name ( ASCII) ; name ( ASCII) Byte 0 0x4D Byte 0 0x4C If the Factor of READ_VOUT of a certain model is 0.01, the communication Bit0 Reserved Low byte HI_TEMP OP_OFF AC_FAIL SHORT OLP OVP OTP FAN_FAIL The conversion of setting and reading values is defined as following:

Among them Factor needs to refer to the definition of SCALING_FACTOR High byte Reserved Reserved Reserved Reserved Reserved Reserved Reserved Actual value= Communication reading value Ч F actor (F value). Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 reading value is 0x0960(hexadecimal)→2400(decimal), EX: Vo_real(actual DC voltage)= READ_VOUT Ч F actor. Bit 0 FAN_FAIL: Fan abnormal state (Not support) Bit 2 OVP: Output over-voltage protection Bit 3 OLP: Output over current protection Bit 1 OTP: Over temperature protection 0=Normal internal temperature 1=Abnormal internal temperature Bit 4 SHORT: Short circuit protection 0=Shorted circuit does not exist then Vo_real = 2400 Ч 0 .01 = 24.00V.

0=Normal output voltage 1=Abnormal output voltage 1=Abnormal output current 1=Shorted circuit protected Bit 5 AC_FAIL: AC abnormal flag 25 Transmission data description: 0=Normal output current 1=Abnormal AC range FAULT_STATUS 0x0040 ( ) 1=abnormal state 0=Normal AC range Bit 6 OP_OFF: DC status 0=Normal state 0=DC turned on 1=DC turned off in each model list.

Low byte 5 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 High byte Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Low byte HI TEMP _ OP OFF _ AC FAIL _ SHORT OLP OVP OTP FAN FAIL _ MFR ID B0B5 _ _ Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 0x4D 0x45 0x41 0x4E 0x57 0x45 MFR ID B6B11 _ _ Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 0x4C 0x4C 0x20 0x20 0x20 0x20 MFR MODEL B0B5 _ _ Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 0x44 0x52 0x53 0x2D 0x34 0x38 MFR ID B6B11 _ _ Byte 6 Byte 7 Byte 8 Byte 9 Byte 10 Byte 11 0x30 0x2D 0x32 0x34 0x20 0x20