mean-well DRS - 240 / 480 Series — Mean Well DRS 240/480 Series Power Supply User Manual PDF

5 Bit 1:2 OPERATION_INIT: Pre-set value of power on operation command 10: 10 minute delay. Write changes to EEPROM if all parameters remain High byte Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Low byte Time_ UPS_ OFF _EN Life_ Test _EN f_EN B uf 01: 1 minute delay. Write changes to EEPROM if all parameters remain Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 00: Immediate. Changes to parameters are written to EEPROM 0: Enable. Parameters to be saved into EEPROM (factory default) Bit 0 _CTRL: CAN CANBus control status (Not support) Bit 3:7 Reserved: Currently not in use, retain (default is 0) 1: Disable.

Parameters NOT to be saved into EEPROM Bus CAN (VOUT_SET, IOUT_SET, OPERATION) Bit 2 EEP_OFF: EEPROM storage function ON/OFF Reserved Reserved Wake_ Up EN _ UPS Delay _ _EN UPS_ Shutdown EN _ 0b00 0x00(OFF) Power OFF, pre-set 0b01 0x01(ON) Power ON, pre-set 0b10= Pre-set is previous set value 0b11= Reserved, currently not in use Bit 0:1 EEP_CONFIG: EEPROM Configuration Note: Not support settings display with “0” immediately (factory default) unchanged for 10 minutes 54 unchanged for 1 minute UPS_CONFIG 0x00D2 ( 11: Reserved 0=SVR Low byte: High Byte:

Bit 2 PFC_OK: Primary side PFC output voltage status(Not support) Bit1 Bit2 Bit3 Bit4 Bit5 Bit6 Bit7 EEP _ - Bit 4 ADL_ON: Active dummy load control state(Not support) Low byte OPERATION_INIT Secondary DD output voltage status TOO LOW Secondary DD output voltage status NORMAL Bit 0:7 Reserved: Currently not in use, retain (default is 0) Bit 1 DC_OK: Secondary DC output voltage status Primary side PFC no starting or abnormal Bit 3 ORING_OFF: ORING MOS OFF(Not support) DD start-up, force control ORING MOS OFF EEP OFF _ - DD start-up, ORING MOS controller ON Active dummy load OFF/Not support Bit 5 INITIAL_STATE: Device initialized status Bit 0 M/S: Parallel mode(Not support) Note:

Not support settings display with “0” - - Bit 6 EEPER: EEPROM data access error Normal EEPROM data access Abnormal EEPROM data access Primary side PFC normal Active dummy load ON NOT in initialization status Bit 7 CHG/UPS: Operation status - - 53 In initialization status SYSTEM_CONFIG 0x00C2 ( ) - - 0 Charging mode 1 UPS mode - 0=Slave 1=Master - Low byte: High byte:

High byte 5 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 High byte Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Low byte Reserved Reserved UPS_ Shutdown_ EN UPS Delay _ EN _ Wake _ Up EN _ Time _ Buff EN _ UPS _ OFF EN _ Life _ Test EN _ Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 High byte - - - - - EEP OFF _ EEP CONFIG _ Low byte - - - - - OPERATION INIT _ CANCTRL _