4 Output Battery Control pin Wire Suggested Torque Wire Suggested Torque Wire Suggested Torque DRS-240 1 -2 AWG 2 6 5Kgf-cm 5 7 . Kgf-cm 1 -2 AWG 2 4 5 7 . Kgf-cm 1 -2 AWG 2 4 2Kgf-cm 1 - AWG 4 30 DRS-480 10-22AWG 10Kgf-cm 8Kgf-cm 10-22AWG 8Kgf-cm 10-22AWG 2Kgf-cm 16-26AWG Connector 3 1 5 7 AC Fail Battery Low DC OK Charger Fail 1 8 4 2 6 8 Terminal Rj45 PIN definition of CN12: JS-2008R-4*2-T or equivalent Address line(A1), reference to PIN2GND(Signal) Address line(A0), reference to PIN2GND(Signal) +3.3V for programmer Reference ground of communication Modbus mode: Communication via Modbus CANBus mode: Communication via CANBus CANL DA/D+ Modbus mode: Communication via Modbus CANBus mode:
Communication via CANBus Force start UPS function Cable selection and suggested torque: Refer to chapter 5.5.1 Refer to chapter 5.5.2 Refer to chapter 5.5.3 Refer to chapter 5.5.4 Terminal Pin No. Assigment (RJ-45) Description NTC connection Terminal Pin No. Assigment (TB4) Wire Suggested Torque Description Description No connection Input 4 2 . Pin ssignment a Open: Normal Short:
Force DC OK Battery low/ Abnormal/ Disconnected Charger fail Function 1 2 3.3V GND 4 RTH+ RTH- Function AC fail Function DB/D- CANH Terminals 5 A0 6 A1 NC Series Pin 3 7,8 Pin 1,2,3 4,5,6 7,8,9 10,11,12 Pin 1,2,3,4,5 6 7 Restart system directly from battery and does not require AC power It is used for monitoring function. Please refer to chapter 4.2 For charging current setting (depend on battery capacity) LED indicator : To show the status of unit. s OFF: , ON:2 3-stage(default) -stage 1 I Terminals of battery connection 4.
User Interface Panel AC Fail Battery Low DC OK Charger Fail Communication Port(RJ45) P lease refer to chapter 5.3.4.1 For Modbus communication 11 4.1 Panel escription d 1 8 N L BAT- BAT+ G H Terminals of DC output Charging curve setting 2 3 Charging curve setting B A Battery start button: Terminals of AC input +V +V -V -V 5 7 CN12 DC OK AC Fail Status Battery Start Charging Current Adj. Alarm signal: 3 1 4 2 6 8 ON 2 1 3 Io ADJ: C D E F A B C D E F G H I 4 Terminals Series DRS-240 Input(G) Output(A) Battery(F) Control pin(C) Wire 12 -26 AWG 10-22AWG Suggested Torque 5Kgf-cm 10Kgf-cm Wire 12 -24 AWG 10-22AWG Suggested Torque 5. 7 Kgf-cm 8Kgf-cm Wire 12 -24 AWG 10-22AWG Suggested Torque 5.
7 Kgf-cm 8Kgf-cm Wire 14 - 30AWG 16-26AWG Suggested Torque 2Kgf-cm 2Kgf-cm DRS-480 Pin Function Description 1 3.3V +3.3V for programmer Connector 2 1 4 3 6 5 8 7 2 GND Reference ground of communication 3 RTH+ NTC connection 4 RTH- 5 A0 Address line(A1), reference to PIN2GND(Signal) 6 7,8 A1 Open: Normal Short:
Force Address line(A0), reference to PIN2GND(Signal) Force start UPS function Pin Function Description Terminal 1,2,3 4,5,6 AC fail DC OK Refer to chapter 5.5.1 Refer to chapter 5.5.2 AC Fail DC OKBatteryCharger Low Fail 7,8,9 Battery low/ Abnormal/ Disconnected Refer to chapter 5.5.3 10,11,12 Charger fail Refer to chapter 5.5.4 Pin Function Description Rj45 1,2,3,4,5 NC No connection 8 1 DB/D- Modbus mode: Communication via Modbus 6 CANH CANBus mode: Communication via CANBus DA/D+ Modbus mode: Communication via Modbus 7 CANL CANBus mode: Communication via CANBus 8 GND-AUX Reference GND of AUX and is isolated from the output terminal. (+V & -V) 2 Charging curve setting 3