DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming the count value will be moved to D1242 and D1243 when interrupt occurs and then the counter will be reset. Program Example 4: EI M1000 I101 M1000 IRET END If interrupt I101 is triggered from input point X1 while C243 is counting, I101 interrupt subroutine executes immediately and the count value in C243 will be moved to D0. After this, C243 is reset. 3-132 Special D D1241, D1240 D1243, D1242 Counter C243 C246 C248 C252 C244 C250 C254 Interrupt X1(I100/I101) X4(I400/I401) X3(I300/I301) X5(I500/I501) DCNT C243 K100 FEND DMOV D1240 D0