Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

3. Instruction Set  There are 6 software zone comparators available exclusively for zone compare operation, hence the limit of 6 comparisons for zone compare does not include the comparisons of  SS2/SA2/12SE does not support software counter C232. DHSCS and DHSCR. 5. Explanations on hardware comparators for HSZ instruction:  Corresponding table for hardware counters and comparators (It is not applicable to VEP-12SE):  Corresponding table for hardware counters and comparators (It is only applicable to VEP-12SE):  Block diagram of hardware counters and comparators:

Hardware comparator A x 4 Set /reset A1 I010 A1 Hardware counter A A Count value Set /reset A4 I040 A4 Hardware comparator B x 4 Set /reset B1 I050 B1 Hardware counter B B Count value Set /reset B4 I080 B4  The two groups can only be used once for each group, occupying 2 comparators. For example, when DHSZ instruction uses A3 and A4 of group A comparators, only the other 2 comparators (A1, A2) are available for DHSCS and DHSCR instructions.  When DHSCS uses I030 or I040, comparators A3 and A4 are no longer available for DHSZ instruction. Also, when DHSCS uses I070 or I080, comparators B3 and B4 are no longer 3-135 A group B group Hardware counter A1 A2 A3 A4 B1 B2 B3 B4 Counter No.

C243, C245~C248, C251,C252 C244, C249, C250, C253, C254 High-speed compare Shares 4 hardware comparators for group A Shares 4 hardware comparators for group B Set/Reset A group B group Hardware counter A1 A2 B1 B2 Counter No. C243, C245~C248, C251,C252 C244 High-speed Shares 2 hardware comparators for group A Shares 2 hardware comparators for group B compare Set/Reset