3. Instruction Set Operands: D : Destination device Explanations: 1. The status of D is alternated every time when the ALT instruction is executed. 2. When ALT instruction is executed, ON/OFF state of D will be switched which is usually applied on switching two operation modes, e.g. Start/Stop 3. This instruction is generally used in pulse execution mode (ALTP). Program Example 1: When X0 goes from OFF to ON, Y0 will be ON. When X0 goes from OFF to ON for the second time, Y0 will be OFF. X0 Y0 Program Example 2:
Creating a flashing circuit by applying ALTP with a timer When X20 = ON, T0 will generate a pulse every two seconds and output Y0 will be switched between ON and OFF by the pulses from T0. X20 T0 3-175 API Mnemonic Operands Function Controllers 66 ALT P Alternate State ES2/EX2 SS2 SA2 SX2 SE Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F ALT, ALTP: 3 steps D * * * PULSE 16-bit 32-bit SA2 SA2 SA2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 SE SE SE ALTP Y0 X0 TMR T0 K20 T0 ALTP Y0 T0 K20