Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming 0 1 2 3 4 5 6 7 8 9 number key BCD value 1-digit BCD code overflow BCD value BIN value D0 2. As shown in the timing diagram below, four keys connected with X35, X33, X31 and X30 are pressed in order. Therefore, the number 5,301 is generated and stored in D0. 9,999 is the maximum value allowed for D0. If the entered number exceeds the available range, the highest 3. When X35 is pressed, M15 remains ON until another key is pressed and the rule applies to digit performs overflow. other inputs. 4. M20 = ON when any of the keys is pressed. 5. When X20 is OFF, the value in D0 remains unchanged but M10~M20 will be OFF.

X30 3 X31 4 X33 2 X35 1 M10 M11 M13 M15 Key output signal M20 1 2 3 4 3-200 103 102 101 100