DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming Sending data: (PLC -> external equipment) source data register, starting from the lower 8 bits of D100 length = 4 Receiving data: (External equipment -> PLC) 3. The STX and ETX of external equipments will be received by PLC in data receiving process, therefore, care should be taken on the setting of operand n (Length of data to be received). 16-bit mode: 1. STX (Start of Text) and ETX (End of text) are set up by M1126 and M1130 together with D1124~D1126. When PLC executed RS instruction, STX and ETX will be sent out automatically. 2. When M1161 = OFF, the 16-bit mode is selected, i.e.
both high byte and low byte of the 16-bit data will be received and transmitted. M1001 M1161 X0 Sending data: (PLC -> external equipment) Source data register, starting from the lower 8 bits of D100 length = 4 3-222 STX D 100L D101L D102L D103L ETX1 ETX2 D120L D121L D122L D123L D124L D125L D126L Registers for received data, STX starting from the lower 8 bits ETX1 ETX2 of D120 length = 7 RS D100 K4 D120 K7 STX D100L D100H D101L D101H ETX1 ETX2