Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

3. Instruction Set Operands: S : rising-edge contact to be connected in series Explanations: ANDP instruction is used in the series connection of the rising-edge contact. Program Example: Ladder Diagram: X1 X0 Y1 Instruction Code: Operation: LD X0 ; Load NO contact of X0 ANDP X1 ; X1 rising-edge contact in series connection OUT Y1 ; Drive Y1 coil 3-277 API Mnemonic Operands Function Controllers 92 ANDP Rising-edge series connection ES2/EX2 SS2 SA2 SX2 SE Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F ANDP: 3 steps S * * * * * * PULSE 16-bit 32-bit SA2 SA2 SA2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 SE SE SE