DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming 103 104 Operands: S 1 : Device address S 2 : Operation frequency of VFD n : Operation mode Explanations: 1. M1177 = OFF (Default), FWD, REV, STOP instructions support COM2(RS-485). 2. M1177= ON, FWD, REV, STOP instructions support COM2(RS-485), COM3(RS-485). 3. M1177 has to be set up in advance for selecting the target model of VFD. When M1177 = OFF (Default), FWD, REV, STOP instructions support Delta’s VFD-A inverter. When M1177 = ON, these instructions support other models of VFD inverters, e.g. VFD-B, VFD. 4.
There is no limitation on the times of using FWD, REV, STOP instruction, however only one instruction can be executed on single COM port at a time. 5. If rising-edge (LDP, ANDP, ORP) or falling-edge (LDF, ANDF, ORF) contacts are used before FWD, REV, STOP instructions, sending request flags M1122 (COM2) / M1316 (COM3) has to be enabled in advance for obtaining correct operation. 6. For detailed information of associated flags and special registers, please refer to RS instruction. 7. M1177 = OFF, only Delta VFD-A is supported and the definition of each operand is: a) S 1 = Address of VFD-A. Range of S 1 : K0 ~ K31 b) S 2 = Operation frequency of VFD. Set value for VFD A-type inverter:
K0 ~ K4,000 (0.0Hz ~ 400.0Hz). c) n = Communication mode. Range: K1 ~ K2. n = 1: communicate with VFD at designated address. n = 2: communicate with all connected VFDs. . 3-296 Mnemonic Operands Function Controllers REV Reverse Operation of VFD ES2/EX2 SS2 SA2 SX2 SE Type OP Bit Devices Word devices Program Steps X Y M S K H K nX KnY KnM KnS T C D E F REV: 7 steps S 1 * * * S 2 * * * n * * * PULSE 16-bit 32-bit SA2 SA2 SA2 S2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 SE SE SE Mnemonic Operands Function Controllers STOP Stop VFD ES2/EX2 SS2 SA2 SX2 SE Type OP Bit Devices Word devices Program Steps X Y M S K H K nX KnY KnM KnS T C D E F STOP:
7 steps S 1 * * * S 2 * * * n * * * PULSE 16-bit 32-bit SA2 SA2 SA2 S2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 SE SE SE