Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming LRC checksum: 01 H + 03 H + 07 H + 08 H + 00 H + 06 H = 19 H. Operate 2’s complement on 19H and the result is E7H. Store ‘E’(45 H) in the low byte of D113 and ‘7’ (37 H) in the low byte of D114. Remarks: ASCII mode communication data: LRC checksum: Operate 2’s complement on the summed up value from communication address to the end of data, i.e. 01 H + 03 H + 21 H + 02 H + 00 H + 02 H = 29 H, the operation result of 29H is D7H. 3-310 STX ‘: ’ Start word = ‘: ’ (3AH) Address Hi ‘ 0 ’ Communication: 8-bit address consists of 2 ASCll codes Address Lo ‘ 1 ’ Function Hi ‘ 0 ’ Function code:

8-bit function consists of 2 ASCll codes Function Lo ‘ 3 ’ DATA (n-1) ……. DATA 0 ‘ 2 ’ Data content: n × 8-bit data consists of 2n ASCll codes ‘ 1 ’ ‘ 0 ’ ‘ 2 ’ ‘ 0 ’ ‘ 0 ’ ‘ 0 ’ ‘ 2 ’ LRC CHK Hi ‘ D ’ LRC checksum: 8-bit checksum consists of 2 ASCll codes LRC CHK Lo ‘ 7 ’ END Hi CR End word: END Hi = CR (0DH), END Lo = LF(0AH) END Lo LF