3. Instruction Set Operands: S : Source device (0° ≦ S < 360°) D : Operation result Explanations: 1. SIN instruction performs sine operation on S and stores the result in D . 2. The value in S can be set as radian or degree by flag M1018. 3. M1018 = OFF, radian mode. RAD = degree Чπ/180. 4. M1018 = ON, degree mode. Degree range: 0° ≦ degree < 360°. 5. Flag: M1018 (Flag for Radian/Degree) 6. See the figure below for the relation between the radian and the operation result: S: Radian R: Result (SIN value) R 1 S -2 3 2 -2 2 3 2 2 2 - 0 - -1 7. If operation result in D is 0, Zero flag M1020 = ON. Program Example 1: M1018 = OFF, radian mode.
When X0 = ON, DSIN instruction conducts sine operation on binary floating value in (D1, D0) and stores the SIN value in (D11, D10) in binary floating format. M1002 X0 D10 D1 D0 RAD value(degree x /180) binary floating point D11 D10 SIN value binary floating point 3-339 API Mnemonic Operands Function Controllers ES2/EX2 SS2 SA2 SX2 130 D SIN P Sine SE Mnemonic Operand s Function Controllers SIN P Sine ES2/EX2 SS2 SA2 SX2 SE Typ e OP Bit Devices X Y M S Word devices Program Steps M S K H KnX KnY Kn M KnS T C D E F DSIN, DSINP: 9 steps S * * * D * PULSE 16-bit 32-bit SA2 2 SE SA2 SA2 ES2/EX2 SS SX2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 SE SE RST M1018 DSIN D0