2. Programming Concepts 2-19 OFF STOP RUN Special ES2 SA2 Latch Function SS2 SX2 Attrib. Default M EX2 SE -ed ON RUN STOP Y2/DDRVI/DDRVA CH1(Y2/Y3) (ON: Enable; OFF: Disable) (available for ES2/EX2: V3.42, ES2-C: V3.48, ES2-E: V1.00, SS2: V3.28, 12SA2: V2.86, 26SE: V2.0, SX2: V2.86, 28SA2: V3.0 or later) M1346* Output clear signals when ZRN is completed ○ ○ ○ ○ OFF - - R/W NO OFF M1347 Auto-reset Y0 when high speed pulse output is completed ○ ○ ○ ○ OFF - - R/W NO OFF M1348 Auto-reset Y1 when high speed pulse output is completed ○ ○ ○ ○ OFF - - R/W NO OFF M1349 When M1349 is ON, the CANopen function is enabled.
(Only for DVP-ES2- C) ○ ╳ ╳ ╳ On - - R/W NO On M1350* Enable PLC LINK ○ ○ ○ ○ OFF - OFF R/W NO OFF M1351* Enable auto mode on PLC LINK ○ ○ ○ ○ OFF - - R/W NO OFF M1352* Enable manual mode on PLC LINK ○ ○ ○ ○ OFF - - R/W NO OFF M1353* Enable access up to 50 words through PLC LINK (If M1353 is ON, D1480~D1511 are latched devices.) ○ ○ ○ ○ OFF - - R/W YES OFF M1354* Enable simultaneous data read/write in a polling of PLC LINK ○ ○ ○ ○ OFF - - R/W NO OFF M1355* Select Slave linking mode in PLC LINK (ON: manual; OFF: auto-detection) ○ ○ ○ ○ - - - R/W YES OFF M1356* Enable station number selection function.
When both M1353 and M1356 are ON, the user can specify the station number in D1900~D1931 ○ ╳ ○ ○ - - - R/W YES OFF M1357* Enabling the detection of X0’s input pulse frequency (ON: Enable; OFF: Disable) V3.2 2 ╳ ╳ V2.6 6 OFF OFF - R/W NO OFF M1358* Enablling the detection of X1’s input pulse frequency (ON: Enable; OFF: Disable) V3.2 2 ╳ ╳ V2.6 6 OFF OFF - R/W NO OFF M1359* Enablling the detection of X2’s input pulse frequency (ON: Enable; OFF:
Disable) V3.2 2 ╳ ╳ V2.6 6 OFF OFF - R/W NO OFF M1360* Slave ID#1 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1361* Slave ID#2 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1362* Slave ID#3 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1363* Slave ID#4 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1364* Slave ID#5 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1365* Slave ID#6 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1366* Slave ID#7 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1367* Slave ID#8 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1368* Slave ID#9 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1369* Slave ID#10 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1370* Slave ID#11 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1371* Slave ID#12 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1372* Slave ID#13 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1373* Slave ID#14 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1374* Slave ID#15 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1375* Slave ID#16 status on PLC LINK network ○ ○ ○ ○ - - - R/W YES OFF M1376* Indicate Slave ID#1 data interchange status on PLC LINK ○ ○ ○ ○ OFF - - R NO OFF M1377* Indicate Slave ID#2 data interchange status on PLC LINK ○ ○ ○ ○ OFF - - R NO OFF M1378* Indicate Slave ID#3 data interchange status on PLC LINK ○ ○ ○ ○ OFF - - R NO OFF M1379* Indicate Slave ID#4 data interchange status on PLC LINK ○ ○ ○ ○ OFF - - R NO OFF M1380* Indicate Slave ID#5 data interchange status on PLC LINK ○ ○ ○ ○ OFF - - R NO OFF M1381* Indicate Slave ID#6 data interchange status on PLC LINK ○ ○ ○ ○ OFF - - R NO OFF