3. Instruction Set k-100, it means that DOG stops immediately after DOG leaves DOG switch and another 100 pulses will be output in the negative direction with JOG frequency. Please refer to state 6 for the timing diagram of this function. (The function supports ES2/EX2 series of V1.40 or above, and SS2/SX2 series of V1.20 or above.) 11. Timing Diagram: State 1: Current position at right side of DOG switch, pulse output in reverse, limit switch disabled. End flag DOG switch: X4/X6 Target freq. JOG freq. Start Meet DOG switch DOG switch OFF State 2: DOG switch is ON, pulse output in reverse, limit switch disabled. Output in reverse End flag M1029/M1102 Off On On Off DOG switch: X4/X6 Freq.