DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming API 179 Operands: S : Source device n : Data length to be summed up D : Device for storing the result Explanations: 1. WSUM instruction sums up n devices starting from S and store the result in D. 2. If the specified source devices S are out of valid range, only the devices in valid range will be processed. 3. Valid range for n : 1~64. If the specified n value is out of the available range (1~64), PLC will take the upper (64) or lower (1) bound value as the set value. 4. D used in the 16-bit/32-bit instruction is a 32-bit register. Program example 1:
When X10 = ON, the 3 consecutive devices ( n = 3) from D0 will be summed up and the result will be stored in (D11, D10) X10 (D0+D1+D2) (D11,D10) D0 K100 D1 K113 (D11,D10) Result: K338 D2 K125 Program example 2: When X10 = ON, 3 consecutive devices ( n = 3) from (D1, D0) will be summed up and the result will be stored in (D11, D10). X10 3-438 Mnemonic Operands Function Controllers D WSUM P Sum of multiple devices ES2/EX2 SS2 SA2 SX2 SE Typ e OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F WSUM, WSUMP: 7 steps DWSUM, DWSUMP:
13 steps S * * * n * * * D * * * PULSE 16-bit 32-bit SA2 SA2 SA2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 SE SE SE WSUM D0 K3 D10 DWSUM D0 K3 D10