Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

3. Instruction Set 3. Operation: When PLC runs and M0 = ON, PLC will start the drawing of the first segment of the arc. D0 will plus 1 whenever a segment of arc is completed and the second segment of the arc will start to execute automatically. The operation pattern repeats until the fourth segment of arc is completed. Program Example 2: 1. Draw a tilted ellipse as the figure below. Y (34000,18000) X (0,0) 2. Steps: a) Find the max. and min. coordinates on X and Y axes (0,0), (26000,26000), (34000,18000), (8000,-8000) (as the figure above). Calculate the relative coordinates of the four points and obtain (26000,26000), (8000,-8000), (-26000,-26000), (-8000,8000).

Place them respectively in the 32-bit registers (D200,D202), (D204,D206), (D208,D210) and (D212,D214). b) Select “draw clockwise arc” and default “motion time” ( S = D100 = K0). c) RUN the PLC. Set ON M0 to start the drawing of a tilted ellipse. = D0 K1 = D0 K2 = D0 K3 = D0 K4 M0 M0 M1029 END 3-465 (26000,260 (8000,-8000) DCIMR D200 D202 D100 Y0 DCIMR D204 D206 D100 Y0 DCIMR D208 D210 D100 Y0 DCIMR D212 D214 D100 Y0 RST M1029 MOV K0 D100 MOV K1 D0 INCP D0