3. Instruction Set 199 Operands: S 1 : Target frequency to be changed S 2 : Gap time and gap frequency D : Pulse output device (Y0, Y2) Explanations: 1. Max frequency for S 1 : 100kHz. When ICF instruction executes, frequecy changing will start immediately with ramp-up/down process. 2. ICF instruction has to be executed after the execution of DVSPO or DPLSY instructions. When the instruction is used together with DVSPO, operands S 1 , S 2 , D of DICF has to be assigned the same device with S 1 , S 3 , D of DVSPO. When the instruction is used with DPLSY, operands S 1 and D has to be assigned the same device with S 1 and D of DPLSY . 3.

If ICF instruction is used with DPLSY instruction, operand S 2 is invalid. 4. When ICF instruction is used with DVSPO instruction, parameter setting of S 2 functions the same as S 3 in DVSPO instruction, specifying the gap time and gap frequency of ramp-up/down process. 5. D pulse output device supports only Y0 and Y2. 6. The instruction is suggested to be applied in interrupt subroutines for obtaining the better response time and eexecution results 7. For associated flags and registers, please refer to Points to note of API 198 DVSPO instruction. Function Explanations: 1.

If users change the target frequency by using DVSPO instruction, the actual changing timing will be delayed due to the program scan time and the gap time as below. Change target freq. Freq. Gap freq. Time Gap time Gap time Delayed by program scan cycle 3-483 Mnemonic Operands Function Controllers D ICF Immediately change frequency ES2/EX2 SS2 SA2 SX2 SE Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F DVSPO: 13 steps S 1 * S 2 * * * D * 16-bit 32-bit SA2 SA2 SA2 SS2 SX2 ES2/EX2 SS2 SX2 ES2/EX2 SS2 SX2 SE SE SE