Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming 206 Operands: S 1 : Address of servo drive (K0~K254) S 2 : Function code S : Register for read/written data Explanations: 1. ASDRW communication instruction supports COM2 (RS-485) and COM3 (RS-485) 2. S 1 : station number of servo drive. Range: K0~K254. K0 indicates broadcasting, i.e. PLC will not receive feedback data. 3. S 2 : function code. Please refer to the table below. 4. S : Register for read/written data. Please refer to the table below for explanations. 5. Explanations of function code:

3-494 Mnemonic Operands Function Controllers ASDRW ASDA servo drive R/W ES2/EX2 SS2 SA2 SX2 SE Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F ASDRW: 7 steps S 1 * * * S 2 * * * S * PULSE 16-bit 32-bit ES2/ SA2/ ES2/ SA2/ ES2/ EX2 SS2 SA2/ SE SX2 SS2 SX2 SS2 SX2 EX2 SE EX2 SE Exclusively for ASDA of A-type, AB type, A+ type, B type Code Function Parameter Com. Addr. Read/Write data (Settings) K0(H0) Status monitor P0-04 ~ P0-08 0004H ~ 0008H S+0 ~ S+4: Please refer to explanations in ASDA manuals. K1(H1) Block Data Read Register P0-09 ~ P0-16 0009H ~ 0010H S+0 ~ S+7: Please refer to explanations in ASDA manuals. B Type is not supported.

K2(H2) Block Data Write Register P0-09 ~ P0-16 0009H ~ 0010H S+0 ~ S+7: Please refer to explanations in ASDA manuals. B Type is not supported. K3(H3) JOG Operation P4-05 0405H S: Range: 1~3000, 4999, 4998, 5000 K4(H4) Servo ON/OFF P2-30 021EH S: K1 = ON, Others = OFF K5(H5) Speed Command (3 sets) P1-09 ~ P1-11 0109H ~ 010BH - S+0 ~ S+2: Range: 5000~+5000 K6(H6) Torque Command (3 sets) P1-12 ~ P1-14 010CH ~ 010EH - S+0 ~ S+2: Range: 300~+300 For A2-type only Code Function Parameter Com. Addr. Read/Write data (Settings) K16(H10) Status monitor (Read) P0-09 ~ P0-13 0012H ~ 001BH S+0 ~ S+9: Please refer to explanations in ASDA-A2 manual.

K17(H11) Status monitor selection (Write) P0-17 ~ P0-20 0022H ~ 0029H S+0 ~ S+7: Please refer to explanations in ASDA-A2 manual. K18(H12) Mapping parameter (Write) P0-25 ~ P0-28 0032H ~ 0039H S+0 ~ S+7: Please refer to explanations in ASDA-A2