3. Instruction Set 271 Operands: S : Reference source device n : Reference bit Explanations: 1. For ES2/EX2 models, only V1.20 or above supports the function. 2. Available range for the value in operand n : K0~K15 for 16-bit instruction; K0~K31 for 32-bit instruction. 3. BAND instruction is used to connect NO contact in series, whose state is defined by the reference bit n in reference device D , i.e. if the bit specified by n is ON, the NO contact will be ON, and vice versa. Program Example: Instruction: Operation:

LDI X1 Load NC contact X1 BAND D0 K0 Connect NO contact in series , whose state is defined by bit0 of D0 OUT Y0 Drive coil Y0 3-511 Mnemonic Operands Function Controllers D BAND Connect NO Contact in Series by Specified Bit ES2/EX2 SS2 SA2 SX2 SE Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F BAND: 5 steps DBAND: 9 steps S * * * * * * n * * * * * * * * * * * PULSE 16-bit 32-bit ES2/ EX2 SS2 SA2/ SE SX2 ES2/ SA2/ ES2/ SA2/ SS2 SX2 SS2 SX2 EX2 SE EX2 SE BAND D0 K0 Y0