Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

3. Instruction Set 8. D tends to occupy more space in the stack area. If the required space exceeds the range of device D , the PLC only executes what is valid in the storage and does not show a no warning. It is suggested that you declare an array of 2xn+4xmxn words for D . 9. There is no limit on the number of times you can execute the instruction but only one execution can be done at a time. 10. It is suggested to use this instruction with the YOUT instruction (API 0710) and use the same first corresponding device for the comparison result in the stack area ( D ). 11. The following timing diagram shows executing the high-speed counter and filter (reading from right to left).

3-531 Function Work station Work station ‧‧‧ Work station 1 2 n Value of the tail index (16-bit) D+n D+(n+1) ‧‧‧ D+(2xn-1) Compared counter result 1 of the object when entering (32-bit) D+2xn D+2xn+2 ‧‧‧ D+2xn+2(n-1) Compared counter result 1 of the object when leaving (32-bit) D+4xn D+4xn+2 ‧‧‧ D+4xn+2(n-1) : : : : : Compared counter result m of the object when entering (32-bit) D+4xmxn-2xn ‧‧‧ D+4xmxn-2 Compared counter result m of the object when leaving (32-bit) D+4xmxn ‧‧‧ D+4xmxn+2 (n-1)