DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming Operands S 1 : Station address of driver S 2 : Driver ON and Driver OFF Explanation 1. The INITC instruction must be complete before this instruction is executed. 2. It is not available for pulse type instructions. Do not use pulse type contact. 3. The range of S 1 is K1–K8 (for servo). There will be no execution when the input value is out of the range. 4. S 2 is a non-zero value, the servo is enabled (Servo-ON). If S 2 is K0, the servo is disabled (Servo-OFF). 5. Each slave ID has an independent flag to show its state; if the flag is ON, it indicates servo drive is ON; if the flag is OFF, it indicates servo drive is OFF. 6.
Any error occurs during operation, M1616 will be set to ON and the servo drive number that shows error will be stored in D6000, error codes in D6001 and STEP that when error occurs in D6002. 3-544 Mnemonic Operands Function Controllers ES2-C ASDON S 1,S 2 Driver ON and OFF Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F ASDON: 5 steps S 1 * * S 2 * * PULSE 16-bit 32-bit -- ES2-C -- Slave R/W ID. 1 ID. 2 ID. 3 ID. 4 ID. 5 ID. 6 ID. 7 ID. 8 Flags for servo drives R M1640 M1641 M1642 M1643 M1644 M1645 M1646 M1647