Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming 339 Operands Node : Specified node ID Mode : Homing mode code Ok : Completion flag Err : Error flag Explanation 1. ZRNM instruction is supported for firmware V3.60 or later. And it can work with Delta special mode. 2. The INITC instruction must be complete before this instruction is executed. 3. The value of Node is in the range of 1~8 (exclusive to servo node IDs). If the setting value exceeds the range, the PLC will not perform the action of the homing mode and set the Err flag to ON. (Refer to explanation of D6001 for error codes.) 4. The ZRNM instruction can set the homing mode of only one drive every time.

If multiple instructions are enabled simultaneously, the PLC will take priority to perform the instruction which is enabled earlier. 5. The ZRNM instruction is executed to send the command when it is enabled. If the instruction is disabled before the Ok flag is on, the PLC will not set the Ok flag to ON. 6. Mode sets a homing mode. If the setting value exceeds the range, the PLC will still send the command and the server itself will decide whether to receive the command or not. The setting mode is the homing mode that ASDA servo parameter P5-04 corresponds to.

3-578 Mnemonic Operands Function Controllers ES2-C ZRNM Node, Mode, Ok, Err Setting the homing mode for Delta servo drive Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F ZRNM: 9 steps Node * * * Mode * * * Ok * Err * PULSE 16-bit 32-bit ES2-C