Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming 3-580 1 = Homing in the reverse direction; NL is the original point. 2 = Homing in the forward direction; ORGP: OFF > ON, as the original point. 3 = Homing in the reverse direction; ORGP: OFF > ON, as the original point. 4 = Homing in the forward direction; look for Z pulse and regard it as the original point. 5 = Homing in the reverse direction; look for Z pulse and regard it as the original point. 6 = Homing in the forward direction; ORGP: ON > OFF, as the original point. 7 = Homing in the reverse direction; ORGP: ON > OFF, as the original point. 8 = Current position is the original point. Homing method:

9~A 9 = Homing in the forward direction; the collision point is the original point. A = Homing in the reverse direction; the collision point is the original point.